Configure the engineering BOM generation > Set properties and relations to be copied to a part in an engineering BOM
Set the copying of the reference designator property to a summarized part
You can use the following steps to set the copying of the reference designator property to a summarized part and configure how it is displayed.
Procedure
- Set the internal name of the reference designator property in the copy preferences for both generation and update scenarios as needed.
- Set the preference BOM_Enable_Ref_Designator_Value_Packing value as true.
- (Optional) You can configure how the reference designator values are displayed after copying them.
After copying, the reference designator values appear on the summarized part as illustrated below:
| Design | Part |
|---|---|
| D_Capacitor (Ref Designator = R1) | P_Capacitor*3 (Ref Designator = R1, R2, R3) |
| D_Capacitor (Ref Designator = R2) | |
| D_Capacitor (Ref Designator = R3) |
In case of released Usage BOM, any modification of reference designator values followed by alignment update may result in the element split.